On 25 June 2012 16:35, jeremy youngs <[email protected]> wrote:
> so andy if i get this right microstep will be 1, 2, 4, 6, 8 ?

Yes, and it will be a setting in the stepper drive (or a fixed value).

it is worth knowing that Stepconf just multiplies together the
microstep, leadscrew pitch and pully diameters to come up with one
single number. So putting a fudge-factor in the microsteps box will
have the desired effect, just in a rather odd way.

>  im going to try 48 and see what happens,
> will making that upgrade increase the rate I can step at thanx

That depends what is currently limiting your step rate. If the motors
run out of torque and stall, then yes. If you are reaching the limit
of software step generation, then no.

-- 
atp