On 25 June 2012 16:35, jeremy youngs <[email protected]> wrote: > so andy if i get this right microstep will be 1, 2, 4, 6, 8 ?
Yes, and it will be a setting in the stepper drive (or a fixed value). it is worth knowing that Stepconf just multiplies together the microstep, leadscrew pitch and pully diameters to come up with one single number. So putting a fudge-factor in the microsteps box will have the desired effect, just in a rather odd way. > im going to try 48 and see what happens, > will making that upgrade increase the rate I can step at thanx That depends what is currently limiting your step rate. If the motors run out of torque and stall, then yes. If you are reaching the limit of software step generation, then no. -- atp If you can't fix it, you don't own it. http://www.ifixit.com/Manifesto ------------------------------------------------------------------------------ Live Security Virtual Conference Exclusive live event will cover all the ways today's security and threat landscape has changed and how IT managers can respond. Discussions will include endpoint security, mobile security and the latest in malware threats. http://www.accelacomm.com/jaw/sfrnl04242012/114/50122263/ _______________________________________________ Emc-developers mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/emc-developers