If you use one input for all limit and home switches then only one axis 
at a time can home and the end of the home move for all axes must not 
leave a switch in the toggled state IIRC.

John

On 11/12/2012 7:38 AM, andy pugh wrote:
> It was my understanding that setting both of these to 1 would allow
> all home and all limit switches to use the same pin.
> Reports from tjb1 seem to indicate that this is not the case.
> I haven't done any testing (no Linux machine to hand) but was the
> intention that these parameters together should be able to allow
> configuration of a single-pin setup?
>


------------------------------------------------------------------------------
Everyone hates slow websites. So do we.
Make your web apps faster with AppDynamics
Download AppDynamics Lite for free today:
http://p.sf.net/sfu/appdyn_d2d_nov
_______________________________________________
Emc-developers mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/emc-developers