On 6 August 2014 00:47, Gene Heskett <[email protected]> wrote: >> Three-phase PWM. > > Something I am not familiar with. 3 phase power, yes, but not pwm.
There is a three-phase PWM generator in your VFD. It drives the 6 individual gates that make up the three-phase bridge. The Mesa 3pwm has 6 (or three) phase-locked PWM channels with a settable dead-time to ensure no shoot-through. -- atp If you can't fix it, you don't own it. http://www.ifixit.com/Manifesto ------------------------------------------------------------------------------ Infragistics Professional Build stunning WinForms apps today! Reboot your WinForms applications with our WinForms controls. Build a bridge from your legacy apps to the future. http://pubads.g.doubleclick.net/gampad/clk?id=153845071&iu=/4140/ostg.clktrk _______________________________________________ Emc-developers mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/emc-developers