This patch allows an integrator to specify the starting RPM of the spindle when started in manual mode. Currently the RPM is always 1, which I dare say most drives cannot actually do.
The capability was in emcmodule for a while (I added it for gscreen), I just forgot about AXIS. The change is very small and defaults to current behavior. Candidate for 2.6.x? If I hear nothing i will just add it to master. Chris M
default_axis_spindle_speed.patch
Description: Binary data
------------------------------------------------------------------------------
_______________________________________________ Emc-developers mailing list Emc-developers@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/emc-developers