On 03/22/2016 06:48 PM, Len Shelton wrote:
> All other settings remaining the same except for the numerical multiplier,
> why is FERROR *not* a simple multiplier when converting a working config
> from INCH to MM?
>
Should be.  FERROR and MIN_FERROR are in "user units", which 
is usually mm or inch.
MIN_FERROR is the amount of permitted error at zero 
velocity. FERROR is a sliding scale
limit that is added to MIN_FERROR.  So, in mm user units, at 
30 mm/min, that is 0.5mm/second,
and so a FERROR = 0.01 would add .01 * 0.5 = .005mm of 
additional tolerance for following error.
But, you have to convert BOTH FERROR and MIN_FERROR.

Jon

------------------------------------------------------------------------------