i'm trying to organize my configs and having trouble doing it conveniently. i'd like to localize external connections in one place and give signals meaningful names. e.g.
net x-neg-limit sscii.0.gpio.0.in-not net x-pos-limit sscii.0.gpio.1.in-not net stop sscii.0.gpio.11.in-not and then use signal names for actual connection: net x-pos-limit => axis.0.pos-lim-sw-in net x-neg-limit => axis.0.neg-lim-sw-in if wiring changes, i can just edit the first net definition. BUT! i also have a pyvcp panel with LEDs showing inputs status. and i can't just write in posgui.hal net led-in0 sscii.0.gpio.0.in-not => pyvcp-led0 because sscii.0.gpio.0.in-not was already named x-neg-limit! so i'm forced to use x-neg-limit name here which ruins routing localization attempt... am i missing something? is there a way to make a connection without referring to a signal name which was given to it before? /dmtiry ------------------------------------------------------------------------------ Find and fix application performance issues faster with Applications Manager Applications Manager provides deep performance insights into multiple tiers of your business applications. It resolves application problems quickly and reduces your MTTR. Get your free trial! https://ad.doubleclick.net/ddm/clk/302982198;130105516;z _______________________________________________ Emc-developers mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/emc-developers