Hello everyone!
I am trying to create custom G70, G71, G72 routines with remap in LinuxCNC master / 2.9.

It was working in 2.8. Now I get such error from an interpreter when loading G-code with G70 present:
G70.0 can only be used in XZ plane (G18)

I have these lines in INI file:
REMAP=G70 modalgroup=1 argspec=w ngc=g70
REMAP=G71 modalgroup=1 argspec=xy> ngc=g71

What is going on here?



_______________________________________________
Emc-developers mailing list
Emc-developers@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/emc-developers

Reply via email to