Greetings all;

one of the problems I am having when using a reasonable speed to search for the edge of a hole is that it does not stop fast enough on first contact, and leaves the probe touching the side of the hole as it spins often enough I get a probe tripped on the next move which recenters the probe so it can find the next side of the hole. Since the move in all cases is one to open the probe contact, which a .1mm move will do, is there a way to make it ignore such a false trigger during the first few milliseconds of the back to center move? Like disabling the probe input when its not a z move after a g38.2 probe move?

Does anybody have a hal solution for what is really a false trigger?
Perhaps firing a 10 millisecond disable it timer with the probe trigger? That should give it time to record the #5061-#5063 data and start the clearing move.

Ideas welcomed.

Thanks all.