Original Text
From: Jerry Fix@EMC Srvc@Eng Hou, on 5/29/96 8:17 AM:
To: smtp[[email protected]]

Good Morning,

Can anyone out there help me with a question on mains (AC) switch markings? 
 My original read on this subject was that the "I" and "0" markings were 
acceptable indicators of on and off.  I have seen in some standards (ie: EN 
60065) a clause that states the "0" can only be used on switches that break 
both sides the supply (line and neutral).  I always assumed that this 
clause referred to the case where you only had a "0" marking (off) and not 
a "I".  Can anyone out there set me straight on this one ?

Thanks,

Jerry Fix, P.E.
Compaq Computer
[email protected]

Reply via email to