Mel,
The requirement can be found in CSA C22.2 No. 950/UL 1950 (Bi-National
Standard) in Annex NAE, Clause No. 3.2.4.
Maximum cord length: 4.5 m
Minimum cord length: 1.5 m (with some exceptions)
These are North American deviations based on the National Electrical Code
and the Canadian Electrical Code.
Best regards,
Dave
EMC Corporation
171 South Street
Hopkinton, MA 01748
508-435-1000, x7518
508-435-5067 (fax)
[email protected] (email)
----------------------[Reply - Original Message]----------------------
Sent by:[email protected] (Mel Jensen)
All;
Can anyone provide guidance as to allowable length(s) for attached power
cords for ITE equipment?
Either e-mail or post responses. And thank you in advance for any and all
help.
Mel Jensen, P.E.
Cray Research, Inc. TEL:715-726-8374
1050 Lowater Rd. FAX:715-726-6715
Chippewa Falls, WI 54729 EMAIL:[email protected]
____________________________________________________________________________
___
=====================================================================