Use a low-noise preamplifier or preselector with integral low noise
preamp.  Companies such as ASI or chesapeake microwave can help you out.
 You may want to start with the EMI receiver manufacturer.

Doug Frazee
EMC Compliance Engineer
Alliant Techsystems, Inc.
Advanced Technology Applications
401 Defense Highway
Annapolis, Maryland  21401
USA
Tel:    (410) 266-1793
FAX:    (410) 266-1853
[email protected]


>----------
>From:  Heck, Stefan[SMTP:[email protected]]
>Sent:  Friday, May 09, 1997 1:34 AM
>To:    'EMC-PSTC (Mail Server)'
>Subject:       MIL-STD-461/462D, RE102, noisefloor
>
>System requirements for RE102
>
>When performing the emission test RE102 according to MIL-STD-461/462D we
>observe that the test system noise floor is at some frequencies just
>below the most stringent limit (navy mobile and army). This is when we
>use the bandwidths prescribed by the standard. We can lower the noise
>level when we reduce the bandwidth. 
>
>Has anybody similar experience? How can we lower the noise floor and at
>the same time fulfill the standard requirements regarding the setup? We
>are using brandnew and high standard test receivers and antennas. 
>
>Any hints are really appreciated!
>
>
> Stefan Heck     _______________________________            phone +47-67
>57 95 06
> [email protected]   /      Senior EMC Engineer     \           FAX    +47-67 57 89 
> 60
>________________/      Det Norske Veritas               
>\________________________
> 
>

Reply via email to