>   Any flammability issues - eg the material of the card etc..?
>   Charles Grasso
>   EMC Engineer
>   StorageTek
>   Tel:(303)673-2908
>   Fax(303)661-7115


Hi Chaz:


Yes.  (I neglected to include this parameter in my response 
to Chris and to the net.)

IEC 950 and its clones require all printed wiring boards to
have a flame-retardant rating V-1 or better.

However, regardless of use of flame-retardant printed wiring
board material, it is far better to prevent overheating in 
the first place.  Flame-retardant materials burn in the
presence of a heat source.  (The advantage of flame-retardant
materials is that they extinguish after the heat source is
removed.)  The purpose of the fuse is to prevent overheating.


Best regards,
Rich



-------------------------------------------------------------
 Richard Nute                             Quality Department 
 Hewlett-Packard Company           Product Regulations Group 
 San Diego Division (SDD)          Tel   :      619 655 3329 
 16399 West Bernardo Drive         FAX   :      619 655 4979 
 San Diego, California 92127       e-mail:  [email protected] 
-------------------------------------------------------------