You should be able to obtain a list of the Japanese national deviations to IEC 950 from UL, CSA, BSI, or other participants in the CB scheme. I obtained a list of the deviations from CSA. This list references IEC 950 amendments 1 & 2.
hope this helps, Mel Pedersen, Midcom, Inc. ---------- From: Dave Clement-LDC009[SMTP:dave_clement-ldc...@email.mot.com] Sent: Tuesday, July 15, 1997 6:18 AM To: emc-p...@ieee.org; t...@world.std.com Subject: RE: Japan safety standards >Could someone help me out with regards to some conflicting information I >have about Japanese safety requirements. > >I have been told 3 different things by 3 different testing organizations >regarding IEC-950 CB scheme requirements. > >1.) Japan accepts only amendments 1 & 2 >2.) Japan accepts amendments 1, 2, or 3 but not amendment 4 >3.) Since it is a CB scheme report, Japan must accept amendment 4 > >All three stated there are specific Japanese deviations. According to CB Bulletin No. 89Al dated DEC. 96 Japan accepts ammendments 1 & 2 and there National Deviations are in Miti Ordinanace No. 85. Dave Clement Motorola ISG