Moshe: We treat the 48V input as a secondary voltage with primary voltage rules. Therefore, you will have to hold to the _reinforced_ distances for creepage and clearance.
Regards, John R. Kretsch, P.E. Compliance Engineering Supervisor ADC Broadband Communications john_kret...@adc.com -----Original Message----- From: mvald...@netvision.net.il [mailto:mvald...@netvision.net.il] Sent: Wednesday, October 21, 1998 03:44 To: emc-p...@ieee.org; t...@world.std.com Subject: isolation of battery (72V max) input Hello everyone, What are creepage/clearance requirements between battery (60V nominal which could go to 72V) conductors and SELV conductors? The equipment resides in "CO like" environment. thanks in advance, Moshe -------------------------------------------- Name: moshe valdman E-mail: mvald...@netvision.net.il Phone: 972-52-941200 Telefax: 972-3-5496369 List-Post: emc-pstc@listserv.ieee.org Date: 21/10/98 Time: 0:44:10 You are most welcome to visit my homepage at: http://www.geocities.com/CapeCanaveral/5233/ -------------------------------------------- --------- This message is coming from the emc-pstc discussion list. To cancel your subscription, send mail to majord...@ieee.org with the single line: "unsubscribe emc-pstc" (without the quotes). For help, send mail to ed.pr...@cubic.com, j...@gwmail.monarch.com, ri...@sdd.hp.com, or roger.volgst...@compaq.com (the list administrators). --------- This message is coming from the emc-pstc discussion list. To cancel your subscription, send mail to majord...@ieee.org with the single line: "unsubscribe emc-pstc" (without the quotes). For help, send mail to ed.pr...@cubic.com, j...@gwmail.monarch.com, ri...@sdd.hp.com, or roger.volgst...@compaq.com (the list administrators).