I would like to compile thoughts and techniques that members of this group 
use to perform "in situ" tests on large industrial apparatus. 
 Considerations I have typically encountered  include:

Current draw in excess of available LISN capacity.  Use CISPR voltage probe
Current draw in excess of available EFT & surge coupling network capacity. 
EFT, use 33nF cap.  Surge,?
3 or 10m EUT to antenna distance not achievable and/or high ambients.
Lab type radiated immunity not practical due to interference potential.
Large equipments requiring multiple antenna locations or search and 
optimize considerations for radiated emissions.

I am especially interested in potential alternate techniques for radiated 
immunity.  Potential solutions may include ad hoc testing using actual 
transmitters, eg cell phones, VHF, etc.  Testing at discrete frequencies of 
known public broadcast bands.  Extended frequency conducted immunity 
testing.

If you have thoughts or other considerations, please respond to the group. 
 As US labs are granted CAB status, consensus on these, and other issues 
will be helpful.

Doug Frazee
Lead Compliance Engineer
Windermere Military/Commercial Compliance Laboratory
Annapolis, MD
USA