Richard,

I agree with your understandings.

It would be risky and open to arguments if understood otherwise.

Mirko Matejic
The Foxboro Company
 ----------
From: WOODS, RICHARD
To: 'EMC'
Subject: Conducted Emissions Test
List-Post: [email protected]
Date: Tuesday, June 23, 1998 1:44PM

My company plans to OEM a video camera that requires a 24 Vac power
source.
The OEM's test data indicates that they did not perform a conducted
emissions test according to EN 55022, yet they have issued a DoC. It is
my
understanding that the OEM must perform the conducted emission test.
Since
they do not market or specify a particular power source, I understand
that
they may test with any source that they may choose. I further understand
that if my company markets or specifies a particular power source, it is
our
responsibility to ensure that the final combination complies with the
conducted emissions limits. Are my understandings correct?

Richard Woods
Sensormatic Electronics
[email protected]
Views expressed by the author do not necessarily represent those of
Sensormatic.