Just a few EMC "stories" about firewire.

We use an 10m long firewire between two parts of one of our products. The   
female connectors had to be improved for ground connection by small metal   
"clips" which both reduced HF emission and improved immunity for fast   
transient according to EN 61000-4-4 (capacitiv clamp).

The ground/shield connection between male and female connectors turned   
out to be poor after the cables had been connected and disconnected   
arround 50 times.

We didn't see other problems than these, data transmission is OK at   
200MHz.

Best regards,

Mr. Kim Boll Jensen
ScanView A/S
Denmark  