For EN 60065 or 60950

Covers or access to hazardous voltages must not be accessible without
the use of a tool, so clips etc. are not satisfactory.

A screwdriver constitutes a tool so screws are the simplest fixing.

> -----Original Message-----
> From: [email protected]
> [SMTP:[email protected]]
> Sent: Monday, June 08, 1998 9:53 AM
> To:   [email protected]
> Subject:      covers over connectors (IEC1010)
> 
> 
> Hello everyone,
> 
> To avoid contact with hazardous voltage in some connectors I need to
> cover them.
> I have 2 questions regarding this:
> 
> 1. Is it OK for the covers to be removed without a tool? (i.e. held
> not by a
> screw but with some kind of reliable clip)
> 
> 2. What should be marked/written on the covers? Will the "exclamation
> mark in a
> triangle" be enough? Do I need to have some text there?
> 
> thanks,
> Moshe Valdman
> 