--- On Wed, 18 Mar 98 12:29:03  [email protected] wrote:

> Subject: EMI gaskets
 
> I am interested in hearing the experiences of anybody out there who has 
> had a need for using EMI gaskets, in particular between metal 
> faceplates of circuit packs in a Telecomms Sub-rack.
 
> We have evaluated BeCu finger stock and foam covered with a metallised 
> fabric and have found the metal fingers out-performed the foam. But, 
> due to customer complaints relating to safety hazards posed by the 
> metal fingers we are being pressured to use the foam. Has anybody else 
> faced similar problems ?
 

---------------End of Original Message-----------------

The customer's aversion to traditional BeCu fingerstock may be due to a worry 
about catching the free side of the fingerstock on fingers or shirt sleeves, 
thus creating a wound hazard, degraded shielding and a need for maintenance.

There is a style of BeCu fingerstock that addresses this problem. Check out 
Spira Engineering's Spira gaskets. In this design, a continuous BeCu ribbon is 
wrapped in a helix around various tubular support cores. Several mounting 
methods are available. This design compares very favorably to the traditional 
fingerstock.

Spira, 818-764-8222, California

--------------------------
Ed Price
[email protected]
Electromagnetic Compatibility Lab
Cubic Defense Systems
San Diego, CA.  USA
619-505-2780