Hi Mat Beware of using EMC surge testers for EN60065. The RC network specified by EN60065 is 1nF/1kohm. I couldn't find any EMC surge tester manufacturer that was willing to supply a unit with this RC network (or if they were, the cost up was ridiculous). I got a quote from a company based in Slovenia -
http://www.testing.si/ and a quote for a custom made unit from a company in Scotland. I can't find the quotes at the moment but I am sure they were a few thousand pounds. In the end I couldn't justify the cost for pre compliance testing, especially as I have never had a product fail this test. If you like, I will dig deeper to find the quotes, please let me know. Regards Chris Colgan EMC & Safety TAG McLaren Audio Ltd mailto:[email protected] > -----Original Message----- > From: Ken Javor [SMTP:[email protected]] > Sent: 19 November 1999 01:12 > To: Aschenberg, Mat; [email protected] > Subject: Re: 10Kv Surge unit to EN60065 standards > > > EMC Master from Netherlands. Repped in US by Richard Janiec on Long > Island. > > ---------- > >From: "Aschenberg, Mat" <[email protected]> > >To: [email protected] > >Subject: 10Kv Surge unit to EN60065 standards > >Date: Thu, Nov 18, 1999, 10:53 AM > > > > > > > Hi all, > > I am looking for a 10KV surge unit. I understand that Keytek has one, > but I > > think that it is overpriced. Does anyone know of a manufacturer that > makes > > these devices? > > It is a European standard, are there European companies making these? > > Thanks, > > Mat Aschenberg > > > > --------- > > This message is coming from the emc-pstc discussion list. > > To cancel your subscription, send mail to [email protected] > > with the single line: "unsubscribe emc-pstc" (without the > > quotes). For help, send mail to [email protected], > > [email protected], [email protected], or > > [email protected] (the list administrators). > > > > > > --------- > This message is coming from the emc-pstc discussion list. > To cancel your subscription, send mail to [email protected] > with the single line: "unsubscribe emc-pstc" (without the > quotes). For help, send mail to [email protected], > [email protected], [email protected], or > [email protected] (the list administrators). > ===================================================== Authorised on 11/19/99 at 09:31:01; code 37f48bf3F5C95060. The contents of this E-mail are confidential and for the exclusive use of the intended recipient. If you receive this E-mail in error, please delete it from your system immediately and notify us either by E-mail, telephone or fax. You should not copy, forward or otherwise disclose the content of the E-mail. TAG McLaren Audio Ltd, The Summit, 11 Latham Road Huntingdon, Cambs, PE18 6ZU Telephone : 01480 415600 (+44 1480 415600) Facsimile : 01480 52159 (+44 1480 52159) --------- This message is coming from the emc-pstc discussion list. To cancel your subscription, send mail to [email protected] with the single line: "unsubscribe emc-pstc" (without the quotes). For help, send mail to [email protected], [email protected], [email protected], or [email protected] (the list administrators).