Bonjour de Montreal,

The Korean rules is requiring the following immunity tests:

ESD : similar to 61000-4-2 
RF immunity : similar to 61000-4-3
EFT : similar to 61000-4-4
Surges : similar to 61000-4-5 (including the 10/700 uS for telecom)
Voltage drops : similar to 61000-4-11 but with different delays than the
European generic or specific standards.

Hope this help.




At 10:42 AM 12/20/1999 -0700, Grasso, Charles (Chaz) wrote:
>
>Hello,
>
>Does anyone in this august body know what immunity
>requirements need to be met?
>
>Is the testing done in country?
>
>---------
>This message is coming from the emc-pstc discussion list.
>To cancel your subscription, send mail to [email protected]
>with the single line: "unsubscribe emc-pstc" (without the
>quotes).  For help, send mail to [email protected],
>[email protected], [email protected], or
>[email protected] (the list administrators).
>
>
>
>


--------------------------------------------------------------------------
Benoit Nadeau, ing. M.ing. (P.Eng., M.Eng)
Gerant du Groupe Conformite (Conformity Group Manager)