Anyone in the business should be able to do this (Lindgren/EMC Test 
Systems/Braden/Panashield, etc.)   -461D/-462D implies absorber lining as
well.  A long time ago, you might have to separately contract to get that,
but no longer.

If you're looking for a particular recommendation, I would try Lindgren
first just for an excuse to talk to Janet O'Neil :-)

----------
From: "David Monreal" <[email protected]>
To: <[email protected]>
Subject: Shielded enclosures
List-Post: [email protected]
Date: Mon, Dec 13, 1999, 3:55 AM


Hi all.

Does anybody design (or know who does) shielded enclosures according to the
followings?

i) Magnetic field
    14kHz about 50dB
    100kHz about 90dB
ii) Electric field
    100kHz about 100dB
    10MHz about 100dB
iii) Plane Wave
    400MHz about 100dB
    1GHz about 100dB

In accordance to MIL-STD 461D and 462D.


Thank you.



David Monreal

Reply via email to