Krzysztof,

For question 2:

EN50082-1:1998 "Electromagnetic compatibility - Generic immunity st7andard
Part 1. Residential, commercial and light industry"

and

EN50082-2:1995 "Electromagnetic compatibility - Generic immunity standard
Part 2. Industrial environment"

Call for both AM80% modulation (over 80-1000MHz) and keyed carrier 50% 
duty cycle (at 900MHz +/- 5MHz) for the radiated RF immunity tests.


Regards,

Jeff Bailey
EMC Technologist
SST - A Division of Woodhead Canada Ltd.
Phone: (519) 725 5136 ext. 363
Fax: (519) 725 1515
Email: [email protected]
Web: www.sstech.on.ca

All comments here are my own and do not necessarily express
the views of SST.



-----Original Message-----
From: [email protected] [mailto:[email protected]]
Sent: Friday, September 24, 1999 6:22 AM
To: [email protected]
Subject: Modulations during Radiated Immunity Tests
Importance: High



Dear Group,
My matter concerns different kinds of modulation used during radiated
immunity tests. For instance: 

IEC 1000-4-3: 1995 describes 80%-depth Amplitude Modulation with a 1kHz
sinwave,

ENV 50204: 1995 describes keyed carrier modulation (on-off, duty cycle
50%).

My question is: do you know any standards (international, national,
technical documentations, etc.) which describes different kind of
modulations than these above (for instance AM with squarewave or
Frequency Modulation or other ways of carrier keying) during tests.
Would you please give me the number and title of the standards,
frequency range, test levels and, of course, parameters of modulation. 

The second question: do you know any product, product family and other
standards which call AM80%1kHz modulation and keyed carrier - cycle duty
50%.

Thank you,
Krzysztof Sieczkarek

Laboratorium Technik Automatycznej Identyfikacji
Instytutu Logistyki i Magazynowania
Poznan, Poland
fax +48 61 8526376
http://www.ilim.poznan.pl/la/index_E.html




---------
This message is coming from the emc-pstc discussion list.
To cancel your subscription, send mail to [email protected]
with the single line: "unsubscribe emc-pstc" (without the
quotes).  For help, send mail to [email protected],
[email protected], [email protected], or
[email protected] (the list administrators).


---------
This message is coming from the emc-pstc discussion list.
To cancel your subscription, send mail to [email protected]
with the single line: "unsubscribe emc-pstc" (without the
quotes).  For help, send mail to [email protected],
[email protected], [email protected], or
[email protected] (the list administrators).

Reply via email to