There is somewhere a HP app note on how to perform CISPR average measurements (by calculating the VBW vs frequency). It was written for the 8566/8568 analyzers Its about 15 yrs old but someone on this list should have it. I lost mine and I don't recall the exact title. What I do, is to use a VBW of 3Hz at 0 span. That seems to correlate with the 8546's built in average detector.
Hans --- John Cronin <[email protected]> wrote: > > Now that we can carry out measurements at 3m I have > another question. How > to perform average measurements above 1 GHz. > > Most analyzers do not appear to have a specific > CISPR compliant average > function. So how is the average measurement carried > out? > > Use of the average detector could yield a few dB > lower levels even for a > narrowband emission. > __________________________________________________ Do You Yahoo!? Bid and sell for free at http://auctions.yahoo.com --------- This message is coming from the emc-pstc discussion list. To cancel your subscription, send mail to [email protected] with the single line: "unsubscribe emc-pstc" (without the quotes). For help, send mail to [email protected], [email protected], [email protected], or [email protected] (the list administrators).