I had the opposite problem once, of ensuring electrical connection to an
anodised aluminium part, for shielding purposes. The only sure way was to
machine away the anodising on the surface where contact was to be made.

But that is quite different from relying on the anodising for insulation,
which I would not have thought a good idea. One scratch, and there is a path
through the conversion coating.

Best regards, Jeff Chambers

-------------------------------------------------------------
Dr Jeff Chambers
Westbay Technology Ltd
Suppliers of EMC Design Software
Tel: +44 1229 869 108
Fax: +44 1229 869 108
http://www.westbay.ndirect.co.uk/westbay1.htm
[email protected]

Main St
Baycliff
Ulverston
Cumbria  LA12 9RN
England
-------------------------------------------------------------


---------