HI!

There is no change for EMS enforcement date (Jan. 2000) in Korea yet.

Applicant for EMI approval could be local company, however, Canada located 
company
could be applicant too since Korea and Canada made MRA.  And, also, EMI label
has to be affixed onto the product as you said.  All ITE product has to have 
EMI label
in market for sale.

I will keep you update for EMS enforcement date if there is any change.

Regards,

Ryan Kim

--------------------- You wrote -------------------


> 
> Hi group,
> 
> Current applicable requirement is EMI only. Testing must be done by a
> recognise test labs and applicant to RRL for EMI approval must be a local
> company. Upon approval, a Korea EMI label with EMI( A or B) indicated, has
> to be affixed onto the product.
> 
> According to my backdated findings, the EMS requirement will be enforced
> soon (January, 2000).
> Do anyone out there has any update or status of this enforcement date?
> 
> I does not seems to see any ITE products in the market having Korea EMI
> label with EMI(A/B)/EMS wording.
> Am I missing something here.
> 
> Regards
> Koh
> 
> 
> ---------
> This message is coming from the emc-pstc discussion list.
> To cancel your subscription, send mail to [email protected]
> with the single line: "unsubscribe emc-pstc" (without the
> quotes).  For help, send mail to [email protected],
> [email protected], [email protected], or
> [email protected] (the list administrators).
> 
> 

---------
This message is coming from the emc-pstc discussion list.
To cancel your subscription, send mail to [email protected]
with the single line: "unsubscribe emc-pstc" (without the
quotes).  For help, send mail to [email protected],
[email protected], [email protected], or
[email protected] (the list administrators).