Argh! For the first time in five years, our NSA is out of spec on our 3
meter OATS at 30 MHz. The problem appears to be the turn table. We can move
the equipment off of the table to one side or toward the front and comply,
so it does not appear to be an off site reflection problem. We have replaced
marginal brushes from the table to the ring and we have added wide copper
ground strips from the ring (attached with screws) to the ground screen
(soldered). Still won't pass. Suggestions?

---------