You may consider using a (big) plastic bag, of known volume. Attach it to the opening where the air comes out. Using a stopwatch you can find the time to fill the bag. Now you know air volume per time thru the PSU.
Regards, Ari > -----Original Message----- > From: EXT Dan Mitchell [mailto:[email protected]] > Sent: Tuesday, May 04, 1999 2:50 AM > To: 'emc-pstc' > Subject: LFM test rig > > > My company produces AC to DC Power Supplies. I have been > directed to make > a quick and dirty test rig that will allow me to put a predetermined > airflow in LFM over the unit. Does anyone know of a website > that describes > something like this or have had experience building such a > test rig and > would be willing to share their expertise. > > > Daniel W. Mitchell > Product Safety Associate Engineer > EOS Corp. > > --------- > This message is coming from the emc-pstc discussion list. > To cancel your subscription, send mail to [email protected] > with the single line: "unsubscribe emc-pstc" (without the > quotes). For help, send mail to [email protected], > [email protected], [email protected], or > [email protected] (the list administrators). > --------- This message is coming from the emc-pstc discussion list. To cancel your subscription, send mail to [email protected] with the single line: "unsubscribe emc-pstc" (without the quotes). For help, send mail to [email protected], [email protected], [email protected], or [email protected] (the list administrators).