You may consider using a (big) plastic bag, of known volume.
Attach it to the opening where the air comes out.
Using a stopwatch you can find the time to fill the bag.
Now you know air volume per time thru the PSU.

Regards,
Ari
> -----Original Message-----
> From: EXT Dan Mitchell [mailto:[email protected]]
> Sent: Tuesday, May 04, 1999 2:50 AM
> To: 'emc-pstc'
> Subject: LFM test rig
> 
> 
> My company produces AC to DC Power Supplies.  I have been 
> directed to make 
> a quick and dirty test rig that will allow me to put a predetermined 
> airflow in LFM over the unit.  Does anyone know of a website 
> that describes 
> something like this or have had experience building such a 
> test rig and 
> would be willing to share their expertise.
> 
> 
> Daniel W. Mitchell
> Product Safety Associate Engineer
> EOS Corp.
> 
> ---------