I apologize, these are questions I should have answered before they were
asked. Our products are all tested and marked to EN 60950 / CSA 950 / UL
1950. All except one have IEC 320 inlets. We ship one of ten power
cordsets with each product. The last product is hard-wired, that is, the
installer connects to a terminal block in the base.

Scott
[email protected]


[email protected] writes:
>Doug, 
>
>What is your product? 
>
>Is it plug & cord connected? (i.e. no reason for an municipal electrical
>inspector to go poking about in the innards)
>
>Or is it hard-wired into a building's circuitry (i.e. electrical
>inspectors
>tend to look into at least the/a main power distribution assembly in the
>equipment)?
>
>For what standards does it carry these UL, CSA and TUV marks?
>
>Regards, 
>Lauren Crane
>Eaton Corporation.  
>
>
>> -----Original Message-----
>> From:        [email protected] [SMTP:[email protected]]
>> Sent:        Tuesday, April 20, 1999 11:10 AM
>> To:  [email protected]
>> Subject:     What Color is Neutral?
>> 
>> Hi Ya'll,
>> 
>> In following the thread about neutral color, I am reminded of a time 12
>> years ago when we had the same discussion here. The end result was my
>> choice to use brown / blue / green/yellow as the primary wiring color
>> scheme through all of our product lines regardless of where they ship.
>> These colors are also forbidden for any other use in our products. We
>have
>> been shipping world wide with that scheme for these 12 years with no
>> problems, and we have carried UL, CSA and TUV marks on these same
>> products.
>> 
>> Scott
>> [email protected]
>> 
>>



---------
This message is coming from the emc-pstc discussion list.