Dear Colleagues,
MIL-STD-461 requires cables to be laid out within 10 cm of the front edge of
the ground plane, which standardizes both RE efficiency and RS coupling.
How about for a reverb test? Is it as important for cables to be near the
ground plane edge, or can they be routed anywhere? Corollary: In a reverb
chamber EUT is not placed near wall as per -461, it is placed away from wall
to guarantee that max field intensities will develop in its vicinity. What
is effect of large ground plane (one twice the mil-std ground plane depth
or more)? Does this diminish field significantly around itself?