Richard,
EN55022 is only for unintentional radiators, or intentional radiators in
stand-by mode.  The applicable radio standard should cover the spurious
emissions above 1 GHz(i.e. ETS 300 328).  I don't see that a competent body
is necessary here.


~~~~~~~~~~~~~~~~~~~~~
Sam Wismer
Lead Regulatory Engineer/
Radio Approvals Engineer
LXE, Inc.
(770) 447-4224 Ext. 3654

Visit Our Website at:
http://www.lxe.com



-----Original Message-----
From: [email protected] [mailto:[email protected]]
Sent: Wednesday, November 15, 2000 4:10 PM
To: [email protected]
Subject: ITE Emissions above 1 GHz



I have an Information Technology device that intentionally generates and
uses 2.45 GHz signals. EN55022 does not provide limits above 1 GHz. Is there
another harmonized EN that can be applied for spurious emissions above 1
GHz? If not, will this product have to be submitted to a Competent Body?

Richard Woods

-------------------------------------------
This message is from the IEEE EMC Society Product Safety
Technical Committee emc-pstc discussion list.

To cancel your subscription, send mail to:
     [email protected]
with the single line:
     unsubscribe emc-pstc

For help, send mail to the list administrators:
     Jim Bacher:              [email protected]
     Michael Garretson:        [email protected]

For policy questions, send mail to:
     Richard Nute:           [email protected]


-------------------------------------------
This message is from the IEEE EMC Society Product Safety
Technical Committee emc-pstc discussion list.

To cancel your subscription, send mail to:
     [email protected]
with the single line:
     unsubscribe emc-pstc

For help, send mail to the list administrators:
     Jim Bacher:              [email protected]
     Michael Garretson:        [email protected]

For policy questions, send mail to:
     Richard Nute:           [email protected]

Reply via email to