Sorry, I forgot to save this thread earlier, and I know we discussed
it.
        If I remember correctly, the issue of North American fuses worked in
Europe under the following conditions
        1) They were internal and only accessible by Service personnel -
E.g. some sort of tool
        2) We supplied the repair depots with fuses with the US fuse size.
(And just what mechanism would monitor that?)

        The real issue is there is no physical size for the fuse that fits
both Europe and the US, Correct.
        If I haven't completely misconstrued that how is it that power inlet
manufactures have NA and European approvals on fused power entry modules?
        
        I apologize for asking this again right after we discussed it - the
memory is going.