Hello to all in the group, I have a little problem. Yeah, I know, but I'm only admitting this one. ; -)
So, here's my dilemma. The problem I 've run into is that equations for distributed capacitance for an microstrip transmission line (plain and embedded) in a PWB found in a couple of references are such that they provide significantly different results. One reference even provides for a mathematical impossibility as a result, however, I am sure that this was a misprint. I do not have access to the applicable IPC spec, so I do not have access to these equations for distributed capacitance for a microstrip transmission line (plain and embedded) in a PWB. If anyone in the group knows the formula from the IPC spec or can look it up for me and send it my way, I would certainly be very grateful. Thank you in advance and I am eagerly awaiting your replies. Best regards, Ron Pickard [email protected] PS - I hope that this does not infringe on any IPC copyright. ------------------------------------------- This message is from the IEEE EMC Society Product Safety Technical Committee emc-pstc discussion list. To cancel your subscription, send mail to: [email protected] with the single line: unsubscribe emc-pstc For help, send mail to the list administrators: Jim Bacher: [email protected] Michael Garretson: [email protected] For policy questions, send mail to: Richard Nute: [email protected]