Hello Friends,

We are getting into faster interconnects that can be affected by the CDNs
called out by EN 61000-4-6.

Has anyone tested a system consisting of an EUT connected to various
peripherals by USB, Firewire, 10 Base T or other bus configurations
considered "high speed" today?  It seems decoupling by an inductor > 280 uH
@ 150 kHz as indicated in the various CDNs in Annex D should cause
considerable signal integrity issues even before the test signal is applied.

If you have tested high speed interconnects to EN 61000-4-6, how did you
manage the signal integrity issues?  Special CDNs?  Special test setup?
This seems like a topic everyone would be interested in.

Just call me curious,