Thanks to all those who responded to my message requesting some input with
regards to test equipment for near-field radiated immunity troubleshooting.
There were MANY suggestions . . . all good ones too.

Ultimately I used an HP Signal Generator and EMCO near-field probes . . .
worked very well . . . simulated the failure within minutes, and fixed the
problem within a couple of hours (poor grounding - paint where the drawing
said there shouldn't be) . . . .

Thanks Again . . .

John Juhasz