Dear All, Does anyone have experience with bridging resitors between TNV-3 to SELV?
1. What is UL's position? 2. What is the European position? TUV and others? 3. What is the position of other countries? My position is that if with the resistors, the circuit can withstand the required impulse and/or electric strength tests, there is no problem. Of course the required clearances and creepages between the resistor and the SELV circuits must be within the specified limits in the standard. Peter Merguerian Managing Director Product Testing Division I.T.L. (Product Testing) Ltd. Hacharoshet 26, POB 211 Or Yehuda 60251, Israel Tel: 972-3-5339022 Fax: 972-3-5339019 e-mail: [email protected] website: http://www.itl.co.il ------------------------------------------- This message is from the IEEE EMC Society Product Safety Technical Committee emc-pstc discussion list. To cancel your subscription, send mail to: [email protected] with the single line: unsubscribe emc-pstc For help, send mail to the list administrators: Jim Bacher: [email protected] Michael Garretson: [email protected] For policy questions, send mail to: Richard Nute: [email protected]