Fully answering this would take several hours and many pages.  The easy 
answer is that total measurement error must be less than the margin between
emissions and the limit.

----------
>From: "Sandy Mazzola" <[email protected]>
>To: [email protected]
>Subject: Full Compliance Versus Pre-Compliance Measurement Systems
>Date: Mon, Jan 24, 2000, 1:37 PM
>

>
> To all,
>
>         Could someone please layout the Fullcompliance EMI Measurement
> system versus Pre-Compliance EMI Measurement system tradeoffs.  Some
> thoughts on when each one is required and when one could get by with the
> pre-compliance setup would be especially helpful.  I know this may be a
> repeat but any thoughts on the matter would be appreciated.
>
>    Thanks in advance for any inputs.
>
>
> Thank You
> Sandy Mazzola
> Symbol Technologies Inc
> 1 Symbol PLaza
> Holtsville, N.Y. 11742
>
>
> ---------
> This message is coming from the emc-pstc discussion list.
> To cancel your subscription, send mail to [email protected]
> with the single line: "unsubscribe emc-pstc" (without the
> quotes).  For help, send mail to [email protected],
> [email protected], [email protected], or
> [email protected] (the list administrators).
>
> 

---------
This message is coming from the emc-pstc discussion list.
To cancel your subscription, send mail to [email protected]
with the single line: "unsubscribe emc-pstc" (without the
quotes).  For help, send mail to [email protected],
[email protected], [email protected], or
[email protected] (the list administrators).

Reply via email to