"John Woodgate" wrote: > Doug McKean inimitably wrote: > > >One of the requirements in 1950 is to > >ground any exposed metal parts accessible to the end user. > > Surely that applies only to Class I products? IF not, it would rule out > Class II and III products entirely. Battery-operated hand-helds are > Class III.
Thanks John, I've deleted the original post. In my haste, I assumed it was Class I and was thinking in regards to a product which used plastic entirely for enclosure, had no chassis ground, and mains primary ground was connected only the power supply chassis. Sorry guys ... - Doug McKean ------------------------------------------- This message is from the IEEE EMC Society Product Safety Technical Committee emc-pstc discussion list. Visit our web site at: http://www.ewh.ieee.org/soc/emcs/pstc/ To cancel your subscription, send mail to: majord...@ieee.org with the single line: unsubscribe emc-pstc For help, send mail to the list administrators: Michael Garretson: pstc_ad...@garretson.org Dave Heald davehe...@mediaone.net For policy questions, send mail to: Richard Nute: ri...@ieee.org Jim Bacher: j.bac...@ieee.org All emc-pstc postings are archived and searchable on the web at: http://www.rcic.com/ click on "Virtual Conference Hall,"