Hi all,
In EN 55024: 1998 Page 9 Paragraph 4.2.1, I found the following
statement: "The application of electrostatic discharges to the contacts of
open connectors is not required by this publication"
My question is twofold has everybody interpreted this to mean that no air
discharges or contact discharges are required to the connector or pins of the
open connector.
And secondly if the answer to the above is no discharges of any type are
required, what other publications would require either air or contact
discharges to open connectors.
Thanks
Sandy Mazzola