Amund, I am going to be simplistic here (excuse me if I left something out) .. . . primarily the differences are with mains voltage rating and the tests that are involved (if you have 'universal input' they will test the product - like temperature testing- at various input voltages) and national deviations. The rest of the text (construction, insulation, wiring, etc.) is nearly identical. When I have my product evaluated to UL 1950, I have them include EN60950 at the same time. It saves a lot of money.
Hope this helps. John Juhasz Fiber Options Bohemia, NY -----Original Message----- From: [email protected] [mailto:[email protected]] Sent: Thursday, April 19, 2001 4:48 AM To: [email protected] Subject: UL1950 vs EN60950 Safety folks, What are the major differences between UL1950 and EN60950 ? Best regards Amund Westin, Oslo/Norway ... still winter ... 25cm powder this morning... -- Get your firstname@lastname email for FREE at http://Nameplanet.com/?su ------------------------------------------- This message is from the IEEE EMC Society Product Safety Technical Committee emc-pstc discussion list. Visit our web site at: http://www.ewh.ieee.org/soc/emcs/pstc/ To cancel your subscription, send mail to: [email protected] with the single line: unsubscribe emc-pstc For help, send mail to the list administrators: Michael Garretson: [email protected] Dave Heald [email protected] For policy questions, send mail to: Richard Nute: [email protected] Jim Bacher: [email protected] All emc-pstc postings are archived and searchable on the web at: http://www.rcic.com/ click on "Virtual Conference Hall,"