Annex A of IEC 61786 specifies the field at the center of a square loop with side dimensions of 2a to be
B = 1.414 u I N / pi / a, where B = the normal field component at the center u = permeability of air I = Current in Amps N = turns If the loop is 1 m square, the field will vary no more than 1% over a 10 cm probe. I have used this loop to calibrate a probe at 58 kHz. Richard Woods ---------- From: [email protected] [SMTP:[email protected]] Sent: Wednesday, January 03, 2001 10:46 AM To: Mirko Matejic; [email protected] Cc: Mothish Subject: Re[2]: assist me Forwarding for Mothish, please keep him on your cc list as you respond. ____________________Reply Separator____________________ --- Mothish <[email protected]> wrote: > > > > > ---------- > > From: Mothish[SMTP:[email protected]] > > Sent: Monday, January 01, 2001 10:24:56 AM > > To: [email protected] > > Subject: assist me > > Auto forwarded by a Rule > > > helo sir, > i got ur email id from iric.com. > iam doing my project work for my engineering > studies.(chennai,tamil > nadu, INDIA) > i have selected magnetic field sensor,for radiated > emmision testing. > i seek ur help for me to know the necessity of loop > calibration(we are > using loop ant. for 20Hz-50KHz range. > plz provide me with the information iam in need of. > or give me some contacts to whom i can clarify my > doubts in future. > > seeking ur help barely. > expecting ur reply. > bye > > SINCERLY, > MOTHISH BABU > ------------------------------------------- This message is from the IEEE EMC Society Product Safety Technical Committee emc-pstc discussion list. To cancel your subscription, send mail to: [email protected] with the single line: unsubscribe emc-pstc For help, send mail to the list administrators: Jim Bacher: [email protected] Michael Garretson: [email protected] For policy questions, send mail to: Richard Nute: [email protected] ------------------------------------------- This message is from the IEEE EMC Society Product Safety Technical Committee emc-pstc discussion list. To cancel your subscription, send mail to: [email protected] with the single line: unsubscribe emc-pstc For help, send mail to the list administrators: Jim Bacher: [email protected] Michael Garretson: [email protected] For policy questions, send mail to: Richard Nute: [email protected]