Hi all Can you help me EN60950 or IEC950 nordic deviation I have an TNV-1 interface (ISDN) on a card going in a computer. Some of my designers told me that we need reinforced isolation transformer(3kv) in Norway. For me, this result is reliant on the host equipment, and whether the host employs a connection to earth. I think that the computer power supply must be reinforced already and the Interface transformer can be only 1.5kv. Do I need 3kv transformer for TNV-1 interface in Norway for pc cards? Thanks
Gaétan Hogue Approvals Manager Eicon Networks Phone: (514) 832-3488 Fax: (514) 745-5588 Email: [email protected] http://www.eicon.com ------------------------------------------- This message is from the IEEE EMC Society Product Safety Technical Committee emc-pstc discussion list. To cancel your subscription, send mail to: [email protected] with the single line: unsubscribe emc-pstc For help, send mail to the list administrators: Jim Bacher: [email protected] Michael Garretson: [email protected] For policy questions, send mail to: Richard Nute: [email protected]