With regard to radiated emission immunity and EN61000-4-3 (or IEC 801-3) I believe there are different field strengths used, depending on the environment in which the apparatus being tested is to be used.
I believe equipment to be used in a well-protected environment may be tested at a lower immunity level than equipment to be used in an unprotected environment. I've ordered a copy of 61000-4-3, but while I'm waiting I'd like to know ASAP: 1) What are the definitions of the levels? 2) What field strengths are used for the various levels? (I think level 2 is 3V/m and level 3 is 10V/m) Regards, Alan ------------------------------------------- This message is from the IEEE EMC Society Product Safety Technical Committee emc-pstc discussion list. Visit our web site at: http://www.ewh.ieee.org/soc/emcs/pstc/ To cancel your subscription, send mail to: [email protected] with the single line: unsubscribe emc-pstc For help, send mail to the list administrators: Ron Pickard: [email protected] Dave Heald: [email protected] For policy questions, send mail to: Richard Nute: [email protected] Jim Bacher: [email protected] All emc-pstc postings are archived and searchable on the web at: http://ieeepstc.mindcruiser.com/ Click on "browse" and then "emc-pstc mailing list"