John & Dorin,
Please clarify as I am not aware of a requirement to isolate Signal
Ground from Frame Ground. Please reference GR-1089-CORE, Section 9.6.2 as
well.
Thx,
Joe
-----Original Message-----
From: John Juhasz [mailto:[email protected]]
Sent: Tuesday, September 10, 2002 11:12 AM
To: 'Dorin'
Cc: 'EMC-PSTC - forum'
Subject: RE: Inrush and EN61000-3-3
Be careful Dorin. For Central Offices, they need to be isolated.
John A. Juhasz
GE Interlogix
Fiber Options Div.
Bohemia, NY
-----Original Message-----
From: Dorin [mailto:[email protected]]
Sent: Tuesday, September 10, 2002 9:12 AM
Cc: 'EMC-PSTC - forum'
Subject: Re: Inrush and EN61000-3-3
Hi,
I am looking for a comparison, pros and cons, on the signal ground
connected versus not connected to the chassis in a telecom system. Any
help is appreciated.
Thanks,
Dorin
-------------------------------------------
This message is from the IEEE EMC Society Product Safety
Technical Committee emc-pstc discussion list.
Visit our web site at: http://www.ewh.ieee.org/soc/emcs/pstc/
To cancel your subscription, send mail to:
[email protected]
with the single line:
unsubscribe emc-pstc
For help, send mail to the list administrators:
Ron Pickard: [email protected]
Dave Heald: [email protected]
For policy questions, send mail to:
Richard Nute: [email protected]
Jim Bacher: [email protected]
All emc-pstc postings are archived and searchable on the web at:
http://ieeepstc.mindcruiser.com/
Click on "browse" and then "emc-pstc mailing list"
-------------------------------------------
This message is from the IEEE EMC Society Product Safety
Technical Committee emc-pstc discussion list.
Visit our web site at: http://www.ewh.ieee.org/soc/emcs/pstc/
To cancel your subscription, send mail to:
[email protected]
with the single line:
unsubscribe emc-pstc
For help, send mail to the list administrators:
Ron Pickard: [email protected]
Dave Heald: [email protected]
For policy questions, send mail to:
Richard Nute: [email protected]
Jim Bacher: [email protected]
All emc-pstc postings are archived and searchable on the web at:
http://ieeepstc.mindcruiser.com/
Click on "browse" and then "emc-pstc mailing list"
-------------------------------------------
This message is from the IEEE EMC Society Product Safety
Technical Committee emc-pstc discussion list.
Visit our web site at: http://www.ewh.ieee.org/soc/emcs/pstc/
To cancel your subscription, send mail to:
[email protected]
with the single line:
unsubscribe emc-pstc
For help, send mail to the list administrators:
Ron Pickard: [email protected]
Dave Heald: [email protected]
For policy questions, send mail to:
Richard Nute: [email protected]
Jim Bacher: [email protected]
All emc-pstc postings are archived and searchable on the web at:
http://ieeepstc.mindcruiser.com/
Click on "browse" and then "emc-pstc mailing list"