British Standards manages to confuse the issue even more by calling the standard "BS EN 61000-3-2:1995 Incorporating Amendments Nos 1, 2, 3 and 4.
I've decided I'm going to put "EN61000-3-2:1995 + A1:1998 + A2:1998 + A14:2000" on the DoC because that's what the OJ seems to want. Chris Colgan Compliance Engineer TAG McLaren Audio Ltd The Summit, Latham Road Huntingdon, Cambs, PE29 6ZU *Tel: +44 (0)1480 415 627 *Fax: +44 (0)1480 52159 * Mailto:[email protected] * http://www.tagmclaren.com > -----Original Message----- > From: John Woodgate [SMTP:[email protected]] > Sent: 16 January 2002 13:54 > To: [email protected] > Subject: Re: which standard have I just tested to? > > > I read in !emc-pstc that Colgan, Chris <[email protected]> > wrote (in <AE0F4BD08FEAD211895900805FE67B1F01090ECA@CAT>) about 'which > standard have I just tested to?', on Wed, 16 Jan 2002: > >I have just tested a product for mains harmonics. I am preparing the > >Declaration of Conformity. My new copy of EN61000-3-2 declares at the > top > >of the cover page it is: > > > >"EN61000-3-2:1995 + A12:1996 + A13:1997 + A1:1998 + A2:1998 + A14:2000" > > > >However if I read the reflist of harmonised standards for the EMC > Directive > >on the Europa website correctly it tells me that A13:1997 was superseded > by > >A1:1998. No mention is made of A12:1996 (withdrawn perhaps?) so the > >reference standard is: > > > >"EN61000-3-2:1995 + A1:1998 + A2:1998 + A14:2000" > > > >Any ideas what I put on my DoC? > > Are you not using the BS EN? If so, cite what it says on the front > cover, which avoids your difficulty. > > I wouldn't worry about A12, if I were you. (;-) > -- > Regards, John Woodgate, OOO - Own Opinions Only. > http://www.jmwa.demon.co.uk > After swimming across the Hellespont, I felt like a Hero. > > ------------------------------------------- > This message is from the IEEE EMC Society Product Safety > Technical Committee emc-pstc discussion list. > > Visit our web site at: http://www.ewh.ieee.org/soc/emcs/pstc/ > > To cancel your subscription, send mail to: > [email protected] > with the single line: > unsubscribe emc-pstc > > For help, send mail to the list administrators: > Michael Garretson: [email protected] > Dave Heald [email protected] > > For policy questions, send mail to: > Richard Nute: [email protected] > Jim Bacher: [email protected] > > All emc-pstc postings are archived and searchable on the web at: > No longer online until our new server is brought online and the old > messages are imported into the new server. ************************************************************** Please visit us at www.tagmclaren.com ************************************************************** The contents of this E-mail are confidential and for the exclusive use of the intended recipient. If you receive this E-mail in error, please delete it from your system immediately and notify us either by E-mail, telephone or fax. You should not copy, forward or otherwise disclose the content of the E-mail. TAG McLaren Audio Ltd The Summit, 11 Latham Road Huntingdon, Cambs, PE29 6ZU Telephone : 01480 415600 (+44 1480 415600) Facsimile : 01480 52159 (+44 1480 52159) ************************************************************** Please visit us at www.tagmclaren.com ************************************************************** ------------------------------------------- This message is from the IEEE EMC Society Product Safety Technical Committee emc-pstc discussion list. Visit our web site at: http://www.ewh.ieee.org/soc/emcs/pstc/ To cancel your subscription, send mail to: [email protected] with the single line: unsubscribe emc-pstc For help, send mail to the list administrators: Michael Garretson: [email protected] Dave Heald [email protected] For policy questions, send mail to: Richard Nute: [email protected] Jim Bacher: [email protected] All emc-pstc postings are archived and searchable on the web at: No longer online until our new server is brought online and the old messages are imported into the new server.