This is my understanding, may be incomplete......

It must withstand reverse polarity connection and remain safe. Doesn't have to 
work afterwards but must not create an unsafe condition ie flame, overheating, 
damaged insulation or live chassis.

The phrase DC only means that it applies if your equipment operates solely from 
DC and will not work with an AC input. There is a presumption that when the 
design accepts AC input it will automatically work with a DC input because with 
an AC design the first component is a rectifier diode.

Best Regards