No this reflecting surfaces mentioned in the standard are objects outside
the specified ellipse
 

Best Regards 

Lothar Schmidt 

Technical Manager EMC/Radio 
BQB 
CETECOM Inc. 
411 Dixon Landing Road 
Milpitas, CA 95035 
* +1 408 586 6214 
* +1 408 586 6299 

-----Original Message-----
From: [email protected] [mailto:[email protected]]
Sent: Friday, November 08, 2002 8:42 AM
To: [email protected]
Subject: CISPR 12 Testing


According to CISPR 12, Section 5.2.1, the OATS requirement calls out "a
clear area free from electromagnetic reflecting surfaces".  Does this imply
that the OATS facility should not have a ground plane or were they referring
to any other electromagnetic reflecting surfaces.  I would appreciate all
input on this topic.
 
Best Regards,
Steve O'Steen
919-554-0901x240
 

Reply via email to