Richard,

In addition to Gherys explanation of the note, there is also the definition
itself that inherently excludes certain interfaces by means of the wordings
widely dispersed and multi-user. But I agree that adding some more
definitions of interfaces would help, also myself.

Clause 6.3:
Telecommunications port
Point of connection for voice , data and signalling transfers intended to
connect widely dispersed systems via such means as direct connection to
multi-user telecom networks (e.g. PSTN, ISDN, xDSL, LAN (token ring,
ethernet, etc) and similar networks.

Note
A port generally intended for connection of components of an ITE system
under test (e.g. RS232, IEEE standard 1284 (parallel printer), USB, IEEE Std
1394 (fire wire) etc) and used in accordance with its functional
specifications ( e.g. for the max. length of cable to be connected to it),
is not considered to be a telecommunications/network port under this
definition 

Regards,
Kris


From: richwo...@tycoint.com [mailto:richwo...@tycoint.com]
Sent: donderdag 30 januari 2003 19:32
To: emc-p...@majordomo.ieee.org
Subject: EN55022:1998 and telecom ports



EN55022:1998 defines telecommunication ports as " Ports which are intended
to be connected to telecommunications networks (e.g. public switched
telecommunication networks, integrated services digital networks), local
area networks (e.g. Ethernet, token ring) and similar networks."

Since "similar networks" are included, it would seem that dissimilar
networks are excluded. What distinguishes a similar network to a dissimilar
network? What are some examples of dissimilar networks that are not
included? 

Richard Woods
Sensormatic Electronics
Tyco International



This message is from the IEEE EMC Society Product Safety
Technical Committee emc-pstc discussion list.

Visit our web site at:  http://www.ewh.ieee.org/soc/emcs/pstc/

To cancel your subscription, send mail to:
     majord...@ieee.org
with the single line:
     unsubscribe emc-pstc

For help, send mail to the list administrators:
     Ron Pickard:              emc-p...@hypercom.com
     Dave Heald:               davehe...@attbi.com

For policy questions, send mail to:
     Richard Nute:           ri...@ieee.org
     Jim Bacher:             j.bac...@ieee.org

Archive is being moved, we will announce when it is back on-line.
All emc-pstc postings are archived and searchable on the web at:
    http://www.ieeecommunities.org/emc-pstc


This message is from the IEEE EMC Society Product Safety
Technical Committee emc-pstc discussion list.

Visit our web site at:  http://www.ewh.ieee.org/soc/emcs/pstc/

To cancel your subscription, send mail to:
     majord...@ieee.org
with the single line:
     unsubscribe emc-pstc

For help, send mail to the list administrators:
     Ron Pickard:              emc-p...@hypercom.com
     Dave Heald:               davehe...@attbi.com

For policy questions, send mail to:
     Richard Nute:           ri...@ieee.org
     Jim Bacher:             j.bac...@ieee.org

Archive is being moved, we will announce when it is back on-line.
All emc-pstc postings are archived and searchable on the web at:
    http://www.ieeecommunities.org/emc-pstc

Reply via email to