From a previous message
> >
> >Could I say we meet "Criteria A, but in a few frequencies we meet criteria
> >B, call for more details."
>
[Chris Maxwell]
I'm wondering if the average user would understand "Criterion A" or
"Criterion B".
Why not use a statement something like: "Operation near radio
interference
sources with frequencies of (list frequencies) may cause (insert your observed
problem). If you notice this type of performance, call tech support."
Chris Maxwell | Design Engineer - Optical Division
email [email protected] | dir +1 315 266 5128 | fax +1 315 797 8024
NetTest | 6 Rhoads Drive, Utica, NY 13502 | USA
web www.nettest.com | tel +1 315 797 4449 |
This message is from the IEEE EMC Society Product Safety
Technical Committee emc-pstc discussion list.
Visit our web site at: http://www.ewh.ieee.org/soc/emcs/pstc/