Doug, the triangle is intended for a "warning" sign and is specified in  ISO
3864. The circle has the meaning of "prohibition or mandatory action," and the
rectangle is for "information including instructions." The diagonal line in a
circle is at 45 degrees. The standard covers all aspects of the design of
these symbols.
 
Richard Woods 
Sensormatic Electronics 
Tyco International 

 
 
 -----Original Message-----
From: POWELL, DOUG [mailto:[email protected]]
Sent: Monday, May 12, 2003 7:53 PM
To: EMC-PSTC (E-mail)
Subject: Use of a triangle on warning labels



Hello group,
 
It has become apparent to me that various standards require triangles at times
when others do not.  For example, IEC 61010-1 Table 1 only indicates 3 symbols
that have the triangle enclosing the symbol.  While, IEC 60417 does not
indicate this.  One that seems to be missing from IEC 61010-1 is the
exclamation point in triangle.  I've reviewed IEC 60204-1, EN50178, EN60950 as
well and I find varying requirements, some more than others.  SEMI S2 seems to
indicate that nearly every symbol belongs in a triangle.
 
I'm guessing that if it is an informational symbol, you do not use the
triangle, but countering this, I have seen the hearing protection warning in a
circle without the triangle.  Does anyone know of a reliable rule-of-thumb for
when to use a triangle on an IEC/ISO international warning symbol?
 
By the way, here's a trivia question to which I do know the answer:
 
On the circle-bar label warning, which angle does the slash take, from 10:00
to 4:00 or from 2:00 to 8:00 on the clock face?
 
 
thanks,
 
-doug
 
Douglas E. Powell 
Regulatory Compliance Engineer 
Advanced Energy Industries, Inc. 
Fort Collins, CO 80535 USA 

 
 
_______________________________________________________________
This message, including any attachments, may contain information
that is confidential and proprietary information of Advanced 
Energy Industries, Inc.  The dissemination, distribution, use 
or copying of this message or any of its attachments is 
strictly prohibited without the express written consent of 
Advanced Energy Industries, Inc.


Reply via email to